Heat pumps are usually cheaper to run than the fossil-fuel and electric-resistance systems they replace, but "cheap" depends almost entirely on three variables: how efficiently the specific unit performs in your climate, what you pay for electricity versus the competing fuel, and how well the building and its distribution system support low-temperature operation.

A heat pump that is well matched to the house can cut annual heating costs substantially; the same unit installed badly, or run in a region with very cheap natural gas and very expensive electricity, can cost more than the system it replaced.

This is a question about operating economics, not sticker price, so it's worth separating the parts that are predictable from the parts that are not.

The efficiency number that actually predicts cost

The figure that drives running cost is not the heat pump's headline efficiency rating but its seasonal performance in your conditions, expressed as a coefficient of performance (COP) or, for the whole year, a seasonal COP. COP is the ratio of heat delivered to energy consumed: a COP of 3 means three units of heat per unit of electricity. That is the entire reason heat pumps can be cheaper—they move heat rather than generate it.

Electric resistance heating has a COP of 1.0 by definition. A modern cold-climate air-source heat pump typically delivers a seasonal COP somewhere around 2.5 to 3.5 in a temperate climate, though the figure falls as outdoor temperature drops and rises in mild weather. Ground-source (geothermal) systems tend to hold a higher and steadier seasonal COP because ground temperature is stable, but they cost far more to install.

Two ratings appear on equipment and are often confused. The HSPF2 rating (heating seasonal performance factor, in Btu per watt-hour) is essentially a seasonal COP expressed in different units; divide HSPF2 by 3.412 to approximate COP. The AHRI-certified capacity ratings tell you output at specific outdoor temperatures. Federal efficiency rules and the exact thresholds vary by region and equipment class, so check the actual model's specification sheet rather than assuming a category number.

The practical point: a heat pump with a seasonal COP of 3 delivers three times as much heat per kilowatt-hour as a resistance heater. That multiplier is the source of any savings, and it shrinks in extreme cold.

The comparison that matters: cost per unit of delivered heat

Running cost is efficiency divided into fuel price. The clean way to compare heating options is cost per million Btu (MMBtu) of delivered heat, or per kilowatt-hour of heat. The arithmetic is simple and worth doing with your own numbers.

For any system, cost per unit of delivered heat = price per unit of input energy ÷ efficiency (as a fraction) ÷ energy content per unit.

A few illustrative calculations, using round numbers only to show the method—substitute your own local prices:

  • Electric resistance: at $0.16/kWh and COP 1.0, one kWh of heat costs $0.16. One kWh equals 3,412 Btu, so that's about $46.90 per MMBtu.
  • Air-source heat pump, seasonal COP 3.0: the same $0.16/kWh electricity yields three kWh of heat per kWh consumed, so cost per kWh of heat is about $0.053, or roughly $15.60 per MMBtu.
  • Natural gas furnace at 95% efficiency: if gas costs $1.20 per therm (100,000 Btu) and the furnace is 95% efficient, delivered heat costs about $1.26 per MMBtu—far below the heat pump figure in this example.

That last line is the crux. In many US markets natural gas has historically been cheap enough per unit of energy that even a good heat pump's efficiency advantage does not always beat it on pure operating cost, especially in milder climates where the heat pump's seasonal COP is high but the gas price is very low.

In regions with expensive gas, cheap off-peak electricity, or no gas connection at all, the heat pump usually wins clearly. Prices move, so the comparison has to be run with current local tariffs, not remembered ones.

Why cold weather changes the math

A heat pump's capacity and efficiency both decline as outdoor temperature falls. At mild temperatures a unit might run at a COP above 3; near its cold-weather limit it may drop toward 1.5–2, and its heating output may no longer match the building's load. Below that point a supplemental resistance strip—COP 1.0—takes over, and running cost rises sharply.

This is why "cold-climate" heat pumps are a distinct category. They are engineered to retain capacity and efficiency at lower temperatures, often specified with rated capacity at 5°F or lower. The exact low-temperature performance is model-specific and should be read from the manufacturer's capacity tables and any independent cold-climate testing, not assumed from the general product type.

The design implication is that a heat pump should be sized and configured so the resistance backup runs as little as possible. A system that leans on strip heat through a cold snap can erase much of its seasonal advantage.

What "cheap to run" looks like in different situations

The honest answer is conditional, and the conditions cluster into recognizable cases.

Usually cheaper than the alternative:

  • Replacing electric resistance baseboard, ceiling heat, or an electric furnace. The efficiency multiplier of 2–3× is large and reliable.
  • Replacing propane, oil, or delivered fuel in areas where those fuels are expensive. Heat pumps frequently beat them on cost per delivered Btu.
  • Homes with no gas service, where the alternative is electric resistance or a delivered fuel.
  • Well-insulated homes in mild-to-moderate climates with a properly sized cold-climate unit.

Sometimes more expensive:

  • Regions with very low natural gas prices relative to electricity, especially older, less efficient homes where a heat pump would need to work hard.
  • Homes with leaky ducts or poor envelope where distribution losses and high load undercut efficiency.
  • Installations where the heat pump is oversized or undersized, or where the backup heat dominates.

Ground-source systems can have the lowest running costs of all in the right application, but the higher installation cost means the operating savings have to be weighed against a much larger upfront outlay. Running cost alone rarely justifies geothermal in a mild climate.

A compact comparison of common heating options

The table compares typical operating-cost characteristics, not specific prices. Efficiency figures are representative ranges; actual performance depends on the model, climate, and installation.

System Typical seasonal efficiency (COP or equivalent) Main operating-cost driver Where it tends to win
Electric resistance 1.0 Electricity price Almost never on cost; simple and cheap to install
Air-source heat pump (standard) ~2.0–3.0 Electricity price, outdoor temperature Mild-to-moderate climates, replacing resistance or delivered fuel
Cold-climate air-source heat pump ~2.0–3.0+ with better cold-weather retention Electricity price, cold-snap performance Cold climates, especially where gas is unavailable or expensive
Natural gas furnace (condensing) ~0.90–0.98 combustion efficiency Gas price Low gas prices, especially in milder climates
Ground-source heat pump ~3.0–4.0+ Electricity price, installation cost Heating- and cooling-dominated loads with space for ground loop

Treat the efficiency ranges as planning aids, not guarantees; verify the exact model's ratings and your local tariffs before relying on any of them.

Hidden running costs people forget

Operating cost is not only the compressor's electricity. A few items regularly surprise owners.

Defrost cycles and auxiliary heat. In cold, humid conditions air-source units periodically reverse to defrost the outdoor coil. This consumes energy and, in some control strategies, triggers backup heat. The effect is real but modest in a well-designed system and larger in poorly configured ones.

Distribution losses. Ducted systems lose conditioned air through leaks and conduction, and those losses apply to heat pumps as much as to furnaces. A ductless mini-split avoids duct losses entirely, which is one reason it can be cheaper to run in a house with problematic ducts.

Pumps, fans, and controls. Ground-source systems run circulating pumps; all systems run indoor and outdoor fans. These are small compared with heating energy but not zero.

Maintenance and refrigerant. Filters, coil cleaning, and occasional refrigerant checks are part of ownership. Refrigerant leaks are uncommon but costly when they happen, and the phase-down of high-global-warming-potential refrigerants is gradually changing what equipment uses.

Rate structure. Time-of-use electricity pricing can make heat pumps cheaper if you pre-heat during off-peak windows and let the building coast, or more expensive if you run during peak hours. This is a tariff question, not an equipment one.

How to estimate your own running cost before buying

You can get a defensible estimate without a contractor's software by working through four steps.

  1. Estimate annual heating load. Take your past heating fuel use, convert it to Btu, and adjust for the efficiency of the old system. A house that used 600 therms of gas at 90% efficiency delivered roughly 54 million Btu of heat. Your new system must deliver about the same, adjusted for envelope improvements and thermostat behavior.
  2. Apply the new system's seasonal efficiency. Divide delivered Btu by the seasonal COP converted to consistent units to get electricity consumption in kWh.
  3. Multiply by your electricity rate, including supply and delivery charges, not just the generation rate. Delivery charges often double the effective price.
  4. Compare with the old system's cost using the same method and its actual fuel price.

Do the arithmetic with your own numbers rather than a rule of thumb; the outcome flips between regions and rate structures, which is why blanket claims about heat pumps being cheap or expensive are unreliable.

A sizing check belongs alongside the cost estimate. An oversized unit short-cycles, which hurts efficiency and humidity control in cooling season; an undersized one leans on backup heat in winter. Ask for a room-by-room load calculation (Manual J or equivalent) rather than a rule-of-thumb size.

Where heat pumps often win on total cost, not just fuel

The running-cost comparison is only part of the picture, and in cooling-dominated climates the heat pump's advantage can be decisive. A heat pump is an air conditioner that runs in reverse, so it replaces both a furnace and a central air conditioner with one machine.

In a home that would otherwise install a furnace plus an AC, the incremental cost of the heat-pump capability can be small, and the cooling-season efficiency is comparable to a good AC.

That dual-function economics matters more than any single heating-season comparison in places where air conditioning is a major load. It also explains why heat pumps are increasingly the default in new construction in many regions.

Incentives and rebates can shift the upfront calculus, but they change by jurisdiction and program cycle and should be checked against current local offerings rather than assumed. They affect payback, not the underlying running-cost comparison.

The bottom line on whether heat pumps are cheap to run

Heat pumps are cheap to run when their seasonal efficiency is high relative to the price of the fuel they replace—most clearly against electric resistance, propane, and oil, and in homes without gas service. They can be more expensive than a condensing gas furnace where gas is very cheap and electricity is not, particularly in milder climates and leaky homes.

The deciding variables are local electricity and fuel prices, climate severity, the specific model's cold-weather performance, and installation quality.

The practical next step is to run the cost-per-delivered-Btu comparison with your own tariffs and a load estimate for your house, then confirm the model's capacity at your design outdoor temperature. That converts a general question into a number specific to your situation.

Frequently Asked Questions

Do heat pumps cost more to run than gas furnaces?

Not universally. In regions where natural gas is inexpensive relative to electricity, a high-efficiency gas furnace can beat a heat pump on heating-season operating cost, especially in milder climates. Where gas is expensive, unavailable, or the home is replacing electric resistance or propane, heat pumps usually cost less to run. The comparison depends on local tariffs and the unit's seasonal efficiency.

Are heat pumps expensive to run in very cold weather?

Their efficiency and capacity decline as it gets colder, and if the system relies on electric resistance backup during cold snaps, running costs rise. Cold-climate heat pumps are designed to retain more capacity and efficiency at low temperatures; the exact performance is model-specific and should be checked against the manufacturer's low-temperature capacity tables.

Is a heat pump cheaper than electric baseboard heat?

Almost always, yes. Electric resistance heat has a COP of 1.0, while a heat pump delivers roughly two to three units of heat per unit of electricity over a season. The savings are substantial wherever a heat pump replaces resistance heating, provided the system is sized and installed correctly.

Do heat pumps lower cooling costs too?

A heat pump cools using the same vapor-compression cycle as a central air conditioner, and a high-efficiency heat pump's cooling performance is broadly comparable to a good AC of similar capacity. In homes that need both heating and cooling, one heat pump can replace two separate systems, which is where the total-cost case is often strongest.

How much does installation affect running costs?

A great deal. Duct leakage, incorrect sizing, poor refrigerant charge, and controls that trigger backup heat too readily all raise operating cost even for efficient equipment. A proper load calculation and commissioning matter as much as the model's rated efficiency.